• Users Online: 188
  • Home
  • Print this page
  • Email this page
Home Current issue Ahead of print Search About us Abstracting and Indexing Editorial board Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2017  |  Volume : 12  |  Issue : 2  |  Page : 165-169

Anterior chamber depth change following cataract surgery in pseudoexfoliation syndrome; a preliminary study


Eye Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran

Correspondence Address:
MD Golshan Latifi
Farabi Eye Hospital, Qazvin Square, Tehran 13336
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jovr.jovr_81_15

Rights and Permissions

Purpose: To assess the pseudophakic anterior chamber depth (PP-ACD) or effective lens position (ELP) change after cataract surgery in patients with pseudoexfoliation syndrome (PEX). Methods: Consecutive eyes with PEX and cataract underwent standard phacoemulsification and were implanted with single-piece acrylic posterior chamber intraocular lenses (IOLs). Eyes with severe PEX and with axial length (AL) greater than 24 mm or less than 22 mm were not included. Eyes with capsular complication or unstable bags that needed capsular tension ring insertion were excluded. The SRK-II formula was applied to calculate IOL power for postoperative emmetropia. PP-ACD or ELP was measured using anterior segment optical coherence tomography. Data obtained at one and six months post operation were evaluated during analysis. Results: Twenty-six eyes of 26 subjects (mean age: 72 years; range: 60–84 years) were studied. PP-ACD was deepened (mean change: 0.08 mm) and a concurrent hyperopic shift (0.3 D) was observed postoperatively between month 1 and month 6 (P values ≤0.002). PP-ACD and postoperative refraction changes were correlated with age and AL (P values <0.025), respectively. Increased hyperopic shift and PP-ACD deepening in eyes with posterior capsule opacification (PCO) was noted postoperatively at six months, but the difference was not statistically significant (P values = 0.15 and 0.2, respectively). Conclusion: After cataract surgery in eyes with PEX syndrome, a significant backward movement of the IOL occurs postoperatively in the first six months, which is associated with a concurrent small hyperopic shift.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed390    
    Printed0    
    Emailed0    
    PDF Downloaded83    
    Comments [Add]    

Recommend this journal